a1
  • Home
  • News
    • Company News
    • Media Coverage
    • Performance Cases
  • Products
    • Energy Storage Management System
    • Charging System
    • Protection Control and Automation of Power Grid
    • Intelligent Power Distribution and Utilization
    • Intelligent Operation and Maintenance System
    • Primary Intelligent Equipment
  • Solutions
    • New Energy
    • Power Plant
    • Power Grid
    • Industry
    • Technical Service
  • About Us
    • About CYG SUNRI
    • Service
    • Training
    • Q&A
    • Message Feedback
中文
EN
摄图网_324846614_用于电力和配电的电气控制面板外壳 不间断 电压安全控制板技术活力电路内阁力量工作建造控制(企业商用)
Energy Storage Management System
·Energy Storage Management System
Charging System
·Charging System
Protection Control and Automation of Power Grid
·Relay Protection ·Communication and Integrated Automation System
Intelligent Power Distribution and Utilization
·Intelligent Power Distribution and Utilization
Intelligent Operation and Maintenance System
·Intelligent Operation and Maintenance System
Primary Intelligent Equipment
·Merging Unit& Smart Terminal ·On-Line Monitoring System of Substation
Relay Protection
https://global.sznari.com/upload/images/product/20230904/16937965166330026.png
BP-2C Busbar Protection
Busbar is an important component of power plant and substation. When there is busbar failure of power plant or substation, if the fault is not removed in time, it may cause damage to many power equipment, affect the stability of power system, and cause power outage in substation. In severe circumstance, it may even cause collapse of the regional power system.Busbar protection is an important secondary system device to ensure safe and stable operation of the power grid, and its safety, reliability, sensitivity and fast response are of decisive significance to guarantee the safety of entire regional power grid. Therefore, it is very necessary to set up a busbar protection with safe operation, reliable action and good performance, so that the fault of busbar can be quickly detected and removed in a timely and selective manner.The BP microcomputer busbar protection independently developed by CYG SUNRI was introduced 1995. With the development of automation, digitization and intelligence of the power system, we have constantly innovated, and successively introduced digital, intelligent and distributed products.
MORE
https://global.sznari.com/upload/images/product/20230904/16937967257586619.png
BP-2CD Busbar Protection
Busbar is an important component of power plant and substation. When there is busbar failure of power plant or substation, if the fault is not removed in time, it may cause damage to many power equipment, affect the stability of power system, and cause power outage in substation. In severe circumstance, it may even cause collapse of the regional power system.Busbar protection is an important secondary system device to ensure safe and stable operation of the power grid, and its safety, reliability, sensitivity and fast response are of decisive significance to guarantee the safety of entire regional power grid. Therefore, it is very necessary to set up a busbar protection with safe operation, reliable action and good performance, so that the fault of busbar can be quickly detected and removed in a timely and selective manner.The BP microcomputer busbar protection independently developed by CYG SUNRI was introduced 1995. With the development of automation, digitization and intelligence of the power system, we have constantly innovated, and successively introduced digital, intelligent and distributed products.
MORE
https://global.sznari.com/upload/images/product/20230904/16937969763978289.png
PRS-753 Line Protection
During the operation of power system, various failures and abnormal operating states may occur. The most common and also the most dangerous failure is the occurrence of various types of short circuits. Line protection mainly aims to address various failures in transmission lines. Different protection models can be selected according to the system conditions, such as single-circuit line, double-circuit line on the same tower, series capacitor compensation line, single channel and dual-channel, and diverse configuration methods can be chosen according to the actual requirements.
MORE
https://global.sznari.com/upload/images/product/20230904/16937968674138964.png
PRS-721 Breaker Protection
During the operation of power system, various failures and abnormal operating states may occur. When the circuit breaker fails, it tends to affect the parallel operation stability of power system. The circuit breaker protection can cut off other related circuit breakers in the same plant and station in a short time limit, so as to minimize the scope of power outage, ensure stable operation of the entire power grid, and avoid serious burning of fault components such as the generator and transformer and the collapse of power grid.
MORE
https://global.sznari.com/upload/images/product/20230904/16937971927303532.png
PRS-7367 Protection and Control Unit
The PRS-7367 is a numerical distributed protection intended for protecting and monitoring various primary apparatus including overhead line, underground cable, transformer, capacitor, etc.
MORE
https://global.sznari.com/upload/images/product/20230904/16937970919241650.png
PRS-778 Transformer Protection
Transformer is important electrical equipment commonly used in power systems. Its safe operation directly decides the power supply and stable operation of power system, especially the large-capacity transformer, and once it is damaged due to failure, the loss will be even greater. Therefore, according to the failure and abnormal working conditions of the transformer, it is necessary to install a relay protection device with reliable operation and good performance according to its capacity and importance.
MORE
https://global.sznari.com/upload/images/product/20230829/16932774793822284.png
PRS-789 Auxiliary Relay
PRS-789-H serial auxiliary relay mostly cooperates with main protection relay to achieve trip circuit supervision, from the positive supply to the negative supply whilst the circuit breaker is open or close status, and as well trip &close activation with self-adaption trip &close coil current, or lockout relay with bi-stable function.
MORE
News
Company News Media Coverage Performance Cases
PRODUCTS
Energy Storage Management System Charging System Protection Control and Automation of Power Grid Intelligent Power Distribution and Utilization Intelligent Operation and Maintenance System Primary Intelligent Equipment
Solutions
New Energy Power Plant Power Grid Industry Technical Service
About Us
About CYG SUNRI Service Training Q&A Message Feedback
OFFICIAL WECHAT
b1
CYG SUNRI is a subsidiary of CYG. Find out more about CYG: www.cyg.com !
Copyright © 2021 CYG Sunri Co., Ltd. All Rights Reserved